The challenge
This homeowner’s Daikin air-to-water heat pump had shut itself down, leaving the house with no heating and no hot water.
It’s a more involved system than most: an outdoor unit behind the garage, an indoor hydro unit in the utility room, a low-loss header, underfloor heating and a hot water cylinder. We hadn’t installed it. He needed someone who could find the real cause of each problem and keep the whole system running, not just reset it and hope.
What we did
Getting it running again (March 2024)
- Opened up the indoor unit and traced the protective shutdown to a faulty flow switch.
- Replaced the flow switch and brought the heat pump back into service, restoring heating and hot water.
Curing flow problems and cleaning the system (May to June 2024)
- Found a sticking Esbe mixing valve and actuator restricting flow around the system, and replaced it.
- Powerflushed the system through the indoor unit.
- Dosed the system with MC1 inhibitor to protect it, then tested everything was working to specification.
A new water pump (November 2024)
- The heat pump was showing a 7H water flow error and the hot water tank switch kept tripping.
- We found the internal water pump was only running intermittently.
- We tried a repair to the pump’s circuit board first, to save the cost of a new pump.
- When that didn’t hold, we checked compatibility, sourced the correct replacement pump and fitted it.
Ongoing care
- At the October 2025 annual service of the heat pump and indoor unit, the underfloor heating wasn’t working.
- We traced it to a faulty Honeywell 22mm two-port zone valve, replaced it and tested the underfloor heating back to full working order.
The result
A complex heat pump system that had stopped altogether is still heating the home and its hot water. Each fault has been traced to its real cause and fixed properly, from the flow switch to the pump, and we always try a sensible repair before reaching for an expensive replacement.
The system is now serviced every year, so small problems get caught before they turn into a cold house.
Photos from the job



Is your heat pump showing error codes, or has it stopped altogether? We repair and service heat pumps, including ones we didn’t install. See our heat pump page or ask us for a quote.
More projects like this
Boilers and heatingFarnhamDIY thermal store to Viessmann boiler and solar, FarnhamA DIY thermal store with pumps, controllers and cables everywhere, replaced by a Viessmann system boiler, twin-coil cylinder and evacuated-tube solar.Read the story
Boilers and heatingFarnhamElectric boiler to Viessmann storage combiAn electric boiler swapped for a Viessmann 111-W storage combi and 440 accumulator, with a new concealed gas run and a hidden leaking cold main fixed.Read the story
Heat pumps and hot waterFernhurstPanasonic heat pump compressor rescue, FernhurstA failed compressor on a Panasonic heat pump we didn't install, replaced to F-Gas standards, then smarter boiler back-up controls and yearly servicing.Read the storyReady when you are
Tell us what you need and we will come back to you with a clear, fixed price. No pressure, no hard sell.